Read the statements carefully and choose the correct option: Statement-I: As per IS 456 : 2000, all columns shall be designed for a minimum eccentricity of L500 + D20, subject to a minimum of 30 mm. Statement-II: For columns under biaxial bending, it is sufficient to ensure that the eccentricity exceeds the minimum value about one axis at a time.
- 1Both Statement-I and Statement-II are false✓
- 2Statement-I is false, but Statement-II is true
- 3Statement-I is true, but Statement-II is false
- 4Both Statement-I and Statement-II are true
Correct answer
Both Statement-I and Statement-II are false