In a single-phase induction energy meter, the lag adjustment is such that the pressure coil flux lags the applied voltage by 88° instead of 90°. What are the percentage errors introduced when measuring power at unity power factor and 0.5 lagging power factor respectively?
- 1-0.061%, -6.1%✓
- 2+0.061%, -5.1%
- 3-0.071%, +6.1%
- 4-7.1%, -6.1%
Correct answer
-0.061%, -6.1%