Computer · Design of Steel Structures
An angle section (used as a tension member) is connected with the longer leg (Net sectional area = 200 mm2) through rivets. The gross sectional area of the outstanding leg is 160 mm2. Calculate the net effective sectional area of the angle, as per IS: 800-2007.
- 1[200 + (15 × 160 / 19)] mm2✓
- 2[200 + (25 × 160 / 29)] mm2
- 3[160 + (25 × 200 / 29)] mm2
- 4[160 + (15 × 200 / 19)] mm2
Correct answer
[200 + (15 × 160 / 19)] mm2