According to IS 456:2000, under what condition can the nominal shear strength of an RC beam section near supports or concentrated loads be enhanced?
- 1Only when the section is located at a distance equal to 3d from the support face
- 2Shear strength enhancement is strictly prohibited near supports
- 3When the section considered is closer to the face of support or concentrated load than twice the effective depth (2d)✓
- 4When the section considered is farther from the face of support than twice the effective depth (2d)
Correct answer
When the section considered is closer to the face of support or concentrated load than twice the effective depth (2d)