Mathematics · Environmental Engineering calculations
A water supply board is responsible for treating 1500 m3/day of water. A settling column analysis indicates that an overflow rate of 20 m/day will produce satisfactory removal for a depth of 3.1 m. It is decided to have two circular settling tanks operating in parallel. What is the required diameter (expressed in m) of each settling tank?
- 13.0
- 24.5
- 39.2
- 46.9✓
Correct answer
6.9