A concrete mix is designed for a characteristic strength of 35 MPa, with a 5% probability that an individual test result falls below it. If the standard deviation for the mix is 4 MPa and the acceptance factor is 1.65, determine the target mean strength.
- 135.0 MPa
- 239.0 MPa
- 336.6 MPa
- 441.6 MPa✓
Correct answer
41.6 MPa