A 40 kVA, single-phase transformer has 400 turns on the primary and 100 turns on the secondary winding. The primary winding is connected to a 2220 V, 50 Hz supply. Determine the maximum value of core flux (Φm).
- 10.0250 Wb✓
- 20.5000 Wb
- 30.0225 Wb
- 41.0000 Wb
Correct answer
0.0250 Wb